[pagetitleshort]
Model: | FDK-D90/H2 |
Prime Power: | 82KW/102KVA |
Standby Power: | 90KW/112KVA |
60Hz/1800rpm/ThreePhase | |
Engine: | Doosan D1146 |
Alternator: | Stamford UCI274C |
[pagetitleshort]
Model: | FDK-D90/H2 |
Prime Power: | 82KW/102KVA |
Standby Power: | 90KW/112KVA |
60Hz/1800rpm/ThreePhase | |
Engine: | Doosan D1146 |
Alternator: | Stamford UCI274C |
Model: | FDK-D90/H2 |
Prime Power: | 82KW/102KVA |
Standby Power: | 90KW/112KVA |
60Hz/1800rpm/ThreePhase |
Engine Model | D1146 |
Engine Manufacturer | Korea Doosan |
Cylinder quantity | 6 |
Cylinder Arrangement | In-line |
Cycle | Four stroke |
Aspiration | Naturally |
Bore x Stroke (mm x mm) | 111×139 |
Displacement | 8.071L |
Compression Ratio | 17.5:1 |
Prime power / Speed (KW/RPM) | 96/1800 |
Standby power/ Speed (KW/RPM) | 105/1800 |
Speed governor | RSV |
Piston Speed | 8.34m/s |
Friction Energy Output | 24kw |
Total Lubrication System Capacity (L) | 15.5 |
Coolant Capacity (L) | 14 |
Fuel Consumption at 100% load (Liters/hr) | 24.7 at 1800rpm |
Starter motor | 24V |
Alternator | 24V |
Engine idle speed | 800-1980rpm |
Alternator model | UCI274C |
Alternator manufacturer | STAMFORD |
Exciter type | Single bearing, Brushless, Self-excited |
Rated output prime power | 118 KVA |
Rated speed | 1800 rpm |
Rated frequency | 60Hz |
Number of phase | 3 |
Rated voltage | 440V (Available with custom requirements) |
Power factor | 0.8 |
Voltage regulation NL-FL | ≤±1% |
Insulation grade | H |
Protection grade | IP23 |
DSE7320 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control and automatically start the engine when the mains are abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automatically shut down the engine and indicate the engine failure.
FDK silent Doosan 90 kw generator is designed by professional acoustic engineers based on years of experience. Now we can make the noise of the generator less than 80-85dB(A) at 1m, or 70-75dB(A) at 7m, 60-65dB(A) at 15m.
Generator set
|
Alternator
|
Low environment Temp
|
ATS
|
|
|
|
|
Fuel system
|
Control system
|
Voltage
|
Synchronized system
|
|
|
|
|
Open
|
Soundproof Version
|
||
Overall Size:L×W×H (mm) | 2150×750×1180 | Overall Size:L×W×H (mm) | 3300×1100×1900 |
Weight (kg) | 1260 | Weight (kg) | 1900 |
Frequency Range / RPM | |
---|---|
Engine Brand | |
Fuel Type | |
Power Output (Standby Power) | |
Application |
Reviews
There are no reviews yet.