310KW UK PERKINS 2206C-E13TAG2 DIESEL 50HZ (original perkins power)

Home/Diesel Generators, 50 HZ, UK Perkins Engine/310KW UK PERKINS 2206C-E13TAG2 DIESEL 50HZ (original perkins power)

310KW UK PERKINS 2206C-E13TAG2 DIESEL 50HZ (original perkins power)

[pagetitleshort]

Model: FDK-P310/H1
Prime Power: 280KW/350KVA
Standby Power: 310KW/388KVA
50Hz/1500rpm/ThreePhase
Engine: Perkins 2206C-E13TAG2
Alternator: Stamford HCI444E

Description

Model: FDK-P310/H1
Prime Power: 280KW/350KVA
Standby Power: 310KW/388KVA
50Hz/1500rpm/ThreePhase

General Features:

  • FDK 350kva generator by UK Perkins power is subjected to a comprehensive performance test which includes 50% load, 70% load, 100% load, 110% load and to check, verify that all control systems, alarm and shut-down protection.
  • Equipped with battery charger and 24V high performance maintenance-free lead-acid starting batteries and connecting cables.
  • Stainless galvanized zinc plates with strong corrosion-proof.
  • Vibration isolators between the engine/alternator and base frame.
  • Equipped with industrial silencer and flexible exhaust hose.
  • Designed to comply with ISO8528/GB2820, standard generator manufacturer.
  • Powered by Perkins engine and coupled with Stamford alternator.
  • Water jacket preheater, oil heater and double air cleaner, etc. are available.

Engine Specifications   (DETAILED in APPENDIX)

Engine Model 2206C-E13TAG2
Engine Manufacturer Perkins UK
Cylinder quantity 6
Cylinder Arrangement In-line
Cycle 4
Aspiration Turbo charged
Bore x Stroke (mm x mm) 130×157
Displacement 12.5 L
Compression Ratio 16.3:1
Prime power / Speed (KW/RPM) 324.2kw/1500
Standby power/ Speed (KW/RPM) 368.4kw/1500
Governor type Electric
Piston Speed N.A.
Typical genset electrical output 280 kw
Total Lubrication System Capacity (L) 40
Total Coolant Capacity (L) 51.4
Fuel Consumption at 100% load (L/hour) 75 L
Starter motor 24V
Alternator 24V
Minimum cranking speed 106 rpm

Alternator Specifications

Alternator model HCI444E
Alternator manufacturer STAMFORD
Exciter type Single bearing, Brushless, Self-excited
Rated output prime power 350KVA
Rated speed 1500 rpm
Rated frequency 50Hz
Number of phase 3
Rated voltage 400V (Available with custom requirements)
Power factor 0.8
Voltage regulation NL-FL ≤±1%
Insulation grade H
Protection grade IP23

Alternator option: Leroy Somer, MECC, Marathon, Engga, Faraday

Control System DSE7320 (DETAILED in INSTRUCTION)

DSE7320 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control and automatically start the engine when the mains are abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automatically shut down the engine and indicate the engine failure.

FEATURES

  • Microprocessor control, with high stability and credibility.
  • Monitoring and measuring operational parameters of the mains supply and genset.
  • Indicating operation status, fault conditions, all parameters and alarms.
  • Multiple protections; multiple parameters display, like pressure, temp. etc.
  • Manual, automatic and remote work mode selectable.
  • Real time clock for time and date display, overall runtime display, 250 log entries.
  • Overall power output display.
  • Integral speed/frequency detecting, telling status of start, rated operation, overspeed etc.
  • Communication with PC via RS485 OR RS232 interface, using MODBUS protocol.

Soundproof Enclosure Specification

FDK silent 350KVA generator by UK original Perkins power is designed by acoustic engineers based on years of experience. Now we can make the noise of the generator less than 80-85dB(A) at 1m, or 70-75dB(A) at 7m, 60-65dB(A) at 15m.

FEATURES

  • Multi-way air intake and exhaust guarantee the power performance of the generator.
  • Large-scale impedance combined type silencer effectively reduce noise of the generator.
  • Internal high performance rubber damper and flexible materials reduce vibration.
  • Base mounted fuel tank supports the generator running for 8 hours.

Optional

Generator set
Alternator
Low environment Temp
ATS
  • Open generator set
  • Silent generator set
  • Trailer generator set
  • ABB MCCB circuit breaker
  • Stamford
  • Marathon
  • Mecc Alte
  • Leroy Somer
  • Farady
  • Engga
  • Water heater
  • Oil heater
  • Battery heater
  • CHINT
  • SCHNEIDER
  • ABB
Fuel system
Control system
Voltage
Synchronized system
  • 12hrs base tank
  • 24hrs base tank
  • Dual wall base fuel tank
  • Outside fuel tank
  • AMF function
  • ATS control cabinet
  • DSE7320
  • DSE7510
  • GU620A
  • 415/240V
  • 400/230V
  • 380/220V
  • 220/127V
  • 200/115V
  • CHINT Cabinet
  • SCHNEIDER Cabinet
  • DSE8610 Module
  • COMAQ Module
  • DEIF Module

 

Dimension & Weight

Open
Soundproof Version
Overall Size:L×W×H (mm) 3800×1500×2400 Overall Size:L×W×H (mm) 4500×2600×3500
Weight (kg) 2800 Weight (kg) 4300

Sales Promises

  • FDK provides a full line of brand new and high quality products. Each and every unit is strictly factory tested before shipment.
  • Quality warranty is according to our standard conditions: 12 months from BL date or 1000 running hours, whichever comes first.
  • Service and parts are available from FDK (lead generation company) or distributors in your location.
  • FDK guarantee use BRAND NEW & GENUINE MACHINE.

Additional information

Frequency Range / RPM

Engine Brand

Fuel Type

Power Output (Standby Power)

Application

Reviews

There are no reviews yet.

Be the first to review “310KW UK PERKINS 2206C-E13TAG2 DIESEL 50HZ (original perkins power)”

Your email address will not be published. Required fields are marked *

Go to Top