[pagetitleshort]
Model: | FDK-P265/H1 |
Prime Power: | 240KW/300KVA |
Standby Power: | 265KW/330KVA |
50Hz/1500rpm/ThreePhase | |
Engine: | Perkins 1606A-E93TAG5 |
Alternator: | Stamford HCI444D |
[pagetitleshort]
Model: | FDK-P265/H1 |
Prime Power: | 240KW/300KVA |
Standby Power: | 265KW/330KVA |
50Hz/1500rpm/ThreePhase | |
Engine: | Perkins 1606A-E93TAG5 |
Alternator: | Stamford HCI444D |
Model: | FDK-P265/H1 |
Prime Power: | 240KW/300KVA |
Standby Power: | 265KW/330KVA |
50Hz/1500rpm/ThreePhase |
Engine Model | 1606A-E93TAG5 |
Engine Manufacturer | Perkins UK |
Cylinder quantity | 6 |
Cylinder Arrangement | In-line |
Cycle | 4 |
Aspiration | Turbo charged |
Bore x Stroke (mm x mm) | 117×146 |
Displacement | 9.3 L |
Compression Ratio | 17.2:1 |
Prime power / Speed (KW/RPM) | 261kw/1500 |
Standby power/ Speed (KW/RPM) | 287kw/1500 |
Governor type | N.A. |
Piston Speed | N.A. |
ElectropaK net engine power | N.A. |
Total Lubrication System Capacity (L) | 36 |
Total Coolant Capacity (L) | N.A. |
Fuel Consumption at 100% load (L/hour) | N.A. |
Starter motor | 24V |
Alternator | 24V |
Minimum cranking speed | N.A. |
Alternator model | HCI444D |
Alternator manufacturer | STAMFORD |
Exciter type | Single bearing, Brushless, Self-excited |
Rated output prime power | 300KVA |
Rated speed | 1500 rpm |
Rated frequency | 50Hz |
Number of phase | 3 |
Rated voltage | 400V (Available with custom requirements) |
Power factor | 0.8 |
Voltage regulation NL-FL | ≤±1% |
Insulation grade | H |
Protection grade | IP23 |
DSE7320 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control and automatically start the engine when the mains are abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automatically shut down the engine and indicate the engine failure.
FDK silent 240KW Perkins engines generator is designed by acoustic engineers based on years of experience. Now we can make the noise of the generator less than 80-85dB(A) at 1m, or 70-75dB(A) at 7m, 60-65dB(A) at 15m.
Generator set
|
Alternator
|
Low environment Temp
|
ATS
|
|
|
|
|
Fuel system
|
Control system
|
Voltage
|
Synchronized system
|
|
|
|
|
Open
|
Soundproof Version
|
||
Overall Size:L×W×H (mm) | 3500×1500×2400 | Overall Size:L×W×H (mm) | 4500×2600×3500 |
Weight (kg) | 2200 | Weight (kg) | 4000 |
Frequency Range / RPM | |
---|---|
Engine Brand | |
Fuel Type | |
Power Output (Standby Power) | |
Application |
Reviews
There are no reviews yet.